FREE VYRCO RESOURCE / 19 / v1.0 / 2026-10-21

Cooling circuits: record before and after

Guide and record for comparing observed mold-circuit conditions without advancing a diagnosis.

Intermediate level | Mold, maintenance, process and quality technicians.

Preserve circuit identity, test configuration, and readings before and after an authorized activity. Supports technical review; by itself, it does not declare that a circuit is clean, leak-free, or fit for production.

Original general guidance from VYRCO. Values and criteria depend on mold design, medium, temperature-control equipment, instruments, and applicable documentation. It prescribes no flow, pressure, temperature, stabilization time, or cleaning method.

Before comparing a circuit

  1. Identify the path. Use the current drawing or diagram to record mold, revision, circuit, inlet, return, and intended flow direction. If a connection or branch cannot be matched to the documentation, mark it pending; do not reassign it by appearance.
  2. Define a safe, authorized condition. Reference the approved procedure, equipment, and limits before connecting, pressurizing, or circulating a medium. Confirm isolation, containment, compatibility, and personal protective equipment through local documentation. This form does not authorize the test.
  3. Preserve the configuration. Record the stated medium and composition, supply source, displayed setting, hoses, connections, valves, adapters, and stabilization time or condition. A reading changes meaning when the setup changes.
  4. Record instruments and locations. Enter the instrument, ID, unit, available verification or calibration status, and exact measurement location. Commercial systems may observe flow, temperature, and pressure, but functions and limits are specific to each model. [DME-FLOW] [PCS-FLOW]
  5. Compare traceable conditions only. Preserve original before-and-after readings, times, and changes made. Reading differences describe what was observed under the recorded conditions; by themselves, they do not prove blockage, corrosion, leakage, thermal improvement, or root cause.
  6. Separate evidence, criterion, and decision. Link the documented criterion and authorized decision maker. Flow calibration addresses points, repetition, reproducibility, and uncertainty; a single field comparison does not replace that process. [NIST-LF] Record pending when evidence is missing.

Fill in the fields in your browser. “Save completed copy” downloads an HTML file with your entries: reopen it to keep editing. “Print / PDF” lets you print or save your entries as a PDF through the print dialog. There is no autosave; save again after each change and before closing. No data is sent to VYRCO.

1 / Circuit identity and configuration

BLANK TEMPLATE. One record per circuit and condition; fictional example kept separate.

2 / Readings, observations, and decision

BLANK TEMPLATE. One record per circuit and condition; fictional example kept separate.

Copy the original indication with its unit. Do not enter zero for an unmeasured value: write not measured or undocumented. Do not calculate a pressure or temperature difference when points, instruments, or conditions are not comparable. Retain original photos and files outside this form.

Original FICTIONAL example

Invented context

Mold DEMO-COOL, revision R-A; fictional circuit C-DEMO-04. Drawing DEMO-DWG-R-A identifies inlet E4 and return R4. Every ID, reading, and event in this example is fictional.

Before condition

Fictional instrument FM-DEMO-01 at the same measurement point. Before indication: 4.80 L/min at 09:10. Temperature and pressure: not measured. The equipment's displayed setting and valve positions were copied to the record.

Recorded activity

Fictional authorized activity ACT-DEMO-07. The form only references the activity and records that the setup was not intentionally changed. It does not describe chemicals, pressure, time, or a cleaning procedure.

After condition

After indication: 5.10 L/min at 09:35, at the same point with FM-DEMO-01. Descriptive difference: +0.30 L/min. No uncertainty, tolerance, flow target, or acceptance criterion was supplied.

Gap identified

Medium composition was not documented and the stabilization condition says pending. Therefore, the form does not declare the conditions fully comparable or attribute the difference to the activity.

Provisional closure

Both indications and the observed change were preserved. Cleanliness, restriction, heat transfer, leakage, cause, and production fitness remain pending authorized review and criteria.

Primary sources and scope

2026-10-21

DME-FLOW - DME FloSense
The manufacturer page describes observing flow, temperature, and pressure, data recording, and sensor locations in cooling circuits. It is used only to support which context may be relevant to record. Its features, alarms, and performance claims belong to FloSense; they are not transferred to other equipment or adopted as VYRCO criteria.

PCS-FLOW - Smartflow Digital Flow Meters
The official page states that these meters detect and display flow and temperature and that the interface can store data or transmit alerts. It is cited as an example of product-specific capability, not a universal procedure or validation of any instrument.

NIST-LF - Fluid Metrology Calibration Services - Liquid Flow
NIST describes its liquid-flow meter calibration services: multiple points, repeated averages, reproducibility assessment, and an uncertainty report. It supports why a field comparison is not a calibration. NIST facility ranges, fluids, and uncertainties are not mold-test values.

Limitations and hold points

Original VYRCO content, an independent project. No employer or customer information. Do not share confidential data. Contact: info@vyrco.com.