VYRCO — Sine and height: check what you are entering V1.0 · 2026-11-04 Input-check guide for technicians manufacturing and inspecting mold components. Intermediate level. Purpose: make a geometry calculation traceable before evaluating a physical setup. This is not a machining procedure or authorization to operate equipment. 1. Identify the length For a simple sine bar, L is the specified center distance of the device; do not use its overall outside length. In the ideal triangle, L is the hypotenuse. Base b is its horizontal projection. Angle θ is measured from horizontal. When θ is nonzero, b and L are not interchangeable. If a drawing uses another angular reference, first document its relationship to θ. 2. Match the equation to your inputs Known center distance: h = L × sin(θ). Known horizontal base: h = b × tan(θ). Both describe a right triangle but use different lengths. For the same triangle, b = L × cos(θ). Record which dimension you know and where it came from. Do not change equations to obtain an expected result. 3. State units and angle format Use one length unit throughout each calculation and record any conversion. The output h retains that unit. Decimal degrees and degrees/minutes/seconds are different formats: 20° 30′ 0″ = 20.5°, not 20.30°. The conversion is degrees + minutes/60 + seconds/3600. If you use radians, label them explicitly. When copying inputs between tools, recheck the unit, format, and angular reference. 4. Review a fictional example All data in this example are fictional and illustrate geometry only. Case A: L = 150 mm and θ = 20°; h = 51.3030215 mm and b ≈ 140.9538931 mm. Case B: b = 150 mm and θ = 20°; h = 54.5955351 mm. These are two different triangles. Confusing the lengths changes the calculated height by approximately 3.2925136 mm in this example. Displayed decimal places support the arithmetic check; they do not specify shop accuracy or a tolerance. 5. Separate calculation from setup The equation produces an ideal height, not a selection of gage blocks or validation of a stack. Before physical use, the responsible person must confirm the equipment configuration and procedure, references and supports, applicable offsets, and verification method. Do not derive an angle limit, load rating, tolerance, or acceptance criterion from this guide. Compound or stepped configurations require their specific documentation. 6. Complete the record Keep original inputs, the unrounded result, the reported value, and the rounding rule approved for the task. Where applicable, check the inverse calculation θ = asin(h/L), with consistent units and angle format. This check can detect some arithmetic discrepancies; it does not verify the physical setup. If the reference, manual, or acceptance criterion is unavailable, mark the item pending and request technical review before using the result in the process. Limitations: Scope: ideal right-triangle geometry and documentation. It does not cover uncertainty, deformation, temperature, surface condition, gage-block selection, workholding, or setup safety assessment. A tool accepting an angle mathematically does not certify that equipment can operate at that angle. Input-check record Editable record — fill in the fields and retain the guide with the record. Do not include confidential information. Initial status: pending review. 1. Record identifier and date: 2. Purpose / component feature: 3. Reference drawing or document and revision: 4. Planned equipment and applicable manual: 5. Known dimension: center distance L or horizontal base b: 6. Original value and unit: 7. Dimension source / evidence: 8. Original angle and geometric reference: 9. Angle format and conversion performed: 10. Selected equation and rationale: 11. Calculated ideal height, including unit: 12. Reported value and rounding rule: 13. Independent check / result: 14. Limitations or pending information: 15. Technical reviewer / decision / date: FICTIONAL SAMPLE RECORD: DEMO-SINE-A. Purpose: check inputs in an exercise. Dimension: center distance L = 150 mm. Angle: 20 decimal degrees from horizontal. Equation: sine. Ideal height: 51.3030215 mm. Drawing/equipment/manual: not applicable to this exercise; no physical setup exists. Decision: mathematical example, not authorized for manufacturing. Manufacturer documentation: Suburban Tool explains center distance, height, and G = C × sin(A), with output in the same unit. Consulted: 2026-11-04. This general reference does not replace the manual for the specific device. Comparisons, worksheet, and example are original VYRCO material; the tangent relationship follows from triangle geometry. https://www.subtool.com/pages/how-to-set-a-simple-sine-plate-bar Free professional use and personal or internal adaptation. Retain VYRCO attribution and label changes; do not resell or distribute modified files as VYRCO originals.