Who it is for and what is included
Intermediate level | Mold, maintenance, process and quality technicians.
Level: Intermediate. Includes instructions, recording fields, a fictional example and reference sources.
How to use it
- Identify the path: Use the current drawing or diagram to record mold, revision, circuit, inlet, return, and intended flow direction. If a connection or branch cannot be matched to the documentation, mark it pending; do not reassign it by appearance.
- Define a safe, authorized condition: Reference the approved procedure, equipment, and limits before connecting, pressurizing, or circulating a medium. Confirm isolation, containment, compatibility, and personal protective equipment through local documentation. This form does not authorize the test.
- Preserve the configuration: Record the stated medium and composition, supply source, displayed setting, hoses, connections, valves, adapters, and stabilization time or condition. A reading changes meaning when the setup changes.
- Record instruments and locations: Enter the instrument, ID, unit, available verification or calibration status, and exact measurement location. Commercial systems may observe flow, temperature, and pressure, but functions and limits are specific to each model. [DME-FLOW] [PCS-FLOW]
- Compare traceable conditions only: Preserve original before-and-after readings, times, and changes made. Reading differences describe what was observed under the recorded conditions; by themselves, they do not prove blockage, corrosion, leakage, thermal improvement, or root cause.
- Separate evidence, criterion, and decision: Link the documented criterion and authorized decision maker. Flow calibration addresses points, repetition, reproducibility, and uncertainty; a single field comparison does not replace that process. [NIST-LF] Record pending when evidence is missing.
Fictional example
Scope and limitations
Does not prescribe flow, pressure, temperature, medium composition, stabilization time, or alarm limits. Does not authorize pressurization, purging, chemical cleaning, compressed air, disassembly, or access to a moving machine or mold. Does not confirm leakage, blockage, corrosion, scale, turbulent regime, heat transfer, or root cause. Cited product specifications are specific to those manufacturers and models; they do not transfer to other equipment. Does not establish calibration, uncertainty, regulatory compliance, mold acceptance, or release to production.
Sources consulted
- DME FloSense
The manufacturer page describes observing flow, temperature, and pressure, data recording, and sensor locations in cooling circuits. It is used only to support which context may be relevant to record. Its features, alarms, and performance claims belong to FloSense; they are not transferred to other equipment or adopted as VYRCO criteria. - Smartflow Digital Flow Meters
The official page states that these meters detect and display flow and temperature and that the interface can store data or transmit alerts. It is cited as an example of product-specific capability, not a universal procedure or validation of any instrument. - Fluid Metrology Calibration Services - Liquid Flow
NIST describes its liquid-flow meter calibration services: multiple points, repeated averages, reproducibility assessment, and an uncertainty report. It supports why a field comparison is not a calibration. NIST facility ranges, fluids, and uncertainties are not mold-test values.
Editorial review: 2026-10-21 · Original forms and general guidance. Always apply the drawing, manual and authorized procedure for your case.